Saliva
Reporting Guidelines - Saliva |
Test |
Results |
Reporting |
Amylase Diffusion
Quantitative |
Positive result (i.e. clearing) for amylase is equal/larger than the 1:100 dilution |
- Elevated levels of amylase were detected on _______ which indicates the presence of saliva.
|
Amylase Diffusion
Quantitative |
Positive result (i.e. clearing) is between the 1:100 dilution and the 1:500 dilution |
- Amylase was detected on _______. Amylase activity at this level has been observed in saliva as well as other biological fluids.
|
Amylase Diffusion
Quantitative |
Positive result (i.e. clearing) is less than the 1:500 dilution |
- Low levels of amylase were detected on _______. Amylase activity at this level is inconclusive for the presence of saliva.
|
Amylase Diffusion
Non-Quantitative |
Positive (i.e. clearing) |
- Analysis of __ gave chemical indications for the presence of amylase, a component of saliva.
|
Amylase Diffusion
Quantitative or Non-Quantitative |
Negative-no amylase activity is observed |
- Amylase, a constituent of saliva, was not detected on _____.
- Analysis of __ failed to give chemical indications for the presence of amylase, a component of saliva.
|